114 4530 d 4 h holgerb /BL-Ctrl_2.0/V0.31/ Hex-Files BL-Ctrl2.0
Adresses 1-8 and 9-12

Attention:
The firmware only works on the original processor with MikroKopter BL2.0 Bootloader
Do not install these files via ISP - only through MKUSB

Changes:
0.30a 2010.09.02 H.Buss
- avoids reported short power-loss

0.31a 2010.10.20 H.Buss
- higher accuracy of temperature measurement > 100°C
- slower power-down in case of overheat

0.31b
- modifications for the 2.0c-Hardware (thicker current-messurement-shunt)
 
113 4546 d 0 h /branches/  
112 4729 d 21 h /branches/  
111 4838 d 5 h holgerb /BL-Ctrl_2.0/V0.31/ Hex-Files BL-Ctrl2.0
Adresses 1-8 and 9-12

Attention:
The firmware only works on the original processor with MikroKopter BL2.0 Bootloader
Do not install these files via ISP - only through MKUSB

Changes:
0.30a 2010.09.02 H.Buss
- avoids reported short power-loss

0.31a 2010.10.20 H.Buss
- higher accuracy of temperature measurement > 100°C
- slower power-down in case of overheat
 
110 4901 d 3 h ingob /tags/V0.42/Hex-Files/BL-Ctrl_V1_1_and_V1_2/ deleted old files  
109 4901 d 3 h ingob /tags/V0.42/Hex-Files/BL-Ctrl_V1_1_and_V1_2/ typo in filename fixed  
108 4956 d 0 h holgerb /BL-Ctrl_2.0/ Hex-Files BL-Ctrl2.0
Adresses 1-8 and 9-12

Attention:
The firmware only works on the original processor with MikroKopter BL2.0 Bootloader
Do not install these files via ISP - only through MKUSB

Changes:
0.30a 2010.09.02 H.Buss
- avoids reported short power-loss
- no selftest if powered via MKUSB
 
107 4956 d 0 h holgerb /BL-Ctrl_2.0/V0.30/ 0.30a 2010.09.02 H.Buss
- avoids short power-loss
- no selftest if powered via MKUSB
 
106 4972 d 0 h holgerb /BL-Ctrl_2.0/ Hex-Files BL-Ctrl2.0
Adresses 1-8 and 9-12

Attention:
The firmware only works on the original processor with MikroKopter BL2.0 Bootloader
Do not install these files via ISP - only through MKUSB
 
105 4972 d 0 h holgerb /BL-Ctrl_2.0/ Hex-Files BL-Ctrl2.0
Adresses 1-8 and 9-12

Attention:
The firmware only works on the original processor with MikroKopter BL2.0 Bootloader
Do not install these files via ISP - only through MKUSB
 
104 4972 d 1 h ingob /BL-Ctrl_2.0/  
103 5027 d 7 h /branches/  
102 5027 d 8 h /branches/V0.37_PA/  
101 5027 d 22 h /branches/V0.37_PA/  
100 5027 d 23 h /branches/V0.37_PA/ Optimierungsversuch der Phasensteuerung
Autor: valbas
 
99 5082 d 0 h ingob /  
98 /  
97 /  
96 /  
95 5280 d 5 h ingob /tags/V0.42/  