Subversion Repositories BL-Ctrl

Rev

Go to most recent revision | Show changed files | Directory listing | RSS feed

Filtering Options

Rev Age Author Path Log message Diff
134 3451 d 8 h holgerb /BL-Ctrl_V3/V1.10/ V1.10
the motors are running even smoother at constant setpoint
 
133 3451 d 8 h holgerb /BL-Ctrl_V3/V1.10/ V1.10
the motors are running even smoother at constant setpoint
 
132 3451 d 8 h holgerb /BL-Ctrl_V3/V1.10/ V1.10
the motors are running even smoother at constant setpoint
 
131 3451 d 8 h holgerb /BL-Ctrl_V3/V1.10/ V1.10
the motors are running even smoother at constant setpoint
 
130 3520 d 3 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014

1.08c 08.08.2014
* small bugfix: If the BL is powered by the MKUSB, the serial interface was deactivated after selftest blinking 6 times
 
129 3520 d 3 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014

1.08c 08.08.2014
* small bugfix: If the BL is powered by the MKUSB, the serial interface was deactivated after selftest blinking 6 times
 
128 3520 d 3 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014

1.08c 08.08.2014
* small bugfix: If the BL is powered by the MKUSB, the serial interface was deactivated after selftest blinking 6 times
 
127 3520 d 3 h holgerb /BL-Ctrl_V3/V1.08/ 1.08c 08.08.2014
-small bugfix: If the BL is powered by the MKUSB, the serial interface was deactivated after selftest
 
126 3541 d 5 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014
 
125 3541 d 5 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014
 
124 3541 d 5 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014
 
123 3541 d 5 h holgerb /BL-Ctrl_V3/V1.08/ Version V1.08
since 18th July 2014
* Redundance: Timout for reporting "No Redundance" reduced from 100 sek to 5 sek
* Default-Timing is 24° again
* There were still some commutation problems with some motors at high currents -> for example U5 (T-Motors) or KDE 4012/4014
 
122 3550 d 7 h holgerb /BL-Ctrl_V3/V1.06/ http://www.mikrokopter.de/ucwiki/BL_V3_Version

Version V1.06 (since 30th June 2014=
* Redundance operation: some small bugfixes in communication
* some small changes in I2C-Data (not important for normal MK operation)
* Small cahnge in selftest procedure
* "ERR:Motor restart" at high current peaks the message "ERR:Motor Restart" could occure instead of "BL-Limitation"
* some motors lost commutation when driving at high currents
* Timing 28° was improved for the case of commutation loss -> please try timing 28 if you have these effects
* Since V1.06e -> default timing is now 28° (in V1.06d and older versions it was 24°)
 
121 3550 d 7 h holgerb /BL-Ctrl_V3/V1.06/ http://www.mikrokopter.de/ucwiki/BL_V3_Version

Version V1.06 (since 30th June 2014=
* Redundance operation: some small bugfixes in communication
* some small changes in I2C-Data (not important for normal MK operation)
* Small cahnge in selftest procedure
* "ERR:Motor restart" at high current peaks the message "ERR:Motor Restart" could occure instead of "BL-Limitation"
* some motors lost commutation when driving at high currents
* Timing 28° was improved for the case of commutation loss -> please try timing 28 if you have these effects
* Since V1.06e -> default timing is now 28° (in V1.06d and older versions it was 24°)
 
120 3550 d 7 h holgerb /BL-Ctrl_V3/V1.06/ http://www.mikrokopter.de/ucwiki/BL_V3_Version

Version V1.06 (since 30th June 2014=
* Redundance operation: some small bugfixes in communication
* some small changes in I2C-Data (not important for normal MK operation)
* Small cahnge in selftest procedure
* "ERR:Motor restart" at high current peaks the message "ERR:Motor Restart" could occure instead of "BL-Limitation"
* some motors lost commutation when driving at high currents
* Timing 28° was improved for the case of commutation loss -> please try timing 28 if you have these effects
* Since V1.06e -> default timing is now 28° (in V1.06d and older versions it was 24°)
 
119 3550 d 8 h holgerb /BL-Ctrl_V3/V1.06/ New directory: BL V3
1.06
 